  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
  • GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
Find Similar Products

Basic Info.

Model NO.
SHINE
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Shape of Core
EE
Capacity
50-30000kVA or Customized
Rated H. V.
10kv & 35kv
Linking Group
Dyn11, Yyn0 or Customized
Insulation Level
IEC Standard
Supply Capacity
4000 Units/Year
Delivery Time
15 Days~1 Month
Transport Package
Container/Plywood Package
Specification
1250X1100X1000
Trademark
Shine or customized
Origin
China
HS Code
8504340000
Production Capacity
4000 Units/Year

Product Description


GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
----Basic structure of dry-type transformer
1. Iron core: stacked by silicon steel sheet, is the magnetic circuit part of the transformer, used to guide the magnetic flux.
2. Winding: divided into high-voltage winding and low-voltage winding, respectively wound on the iron core, used to realize the conversion and transmission of electric energy.
3. Insulating cylinder: placed between high and low voltage coils, used to increase electrical insulation and ensure the safe operation of the transformer.
4. pads: used to support and restrain the coils to maintain their stability and shape.
5. Fasteners: used to connect and fix each part of the transformer, with anti-loosening performance.

 
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer




----Overview:
10kV & 35Kv dry-type transformer is a kind of transformer whose core and windings are not immersed in insulating liquid, which has the advantages of safety, fire prevention, no pollution, etc. It is widely used in power systems in industrial, commercial and civil fields.

----Main features:
Superior safety performance: fireproof, no pollution, can run directly in the load center, improve system safety.
High mechanical strength: strong short-circuit resistance, small partial discharge, good thermal stability, long service life.
Remarkable energy-saving effect: low loss, low noise, high operating efficiency, in line with modern energy saving and environmental protection requirements.
Excellent heat dissipation performance: good heat dissipation performance, strong operating capacity, forced air-cooling can increase the capacity of operation.
Strong environmental adaptability: good moisture-proof performance, adapting to high humidity and other harsh environments.
Low maintenance cost: environmentally friendly, flame retardant, explosion-proof, maintenance-free and other features, reducing operation and maintenance costs.
Small size and light weight: easy transportation and installation, space saving.

----After-sales service:
Provide comprehensive pre-sales consulting and program design services.
Provide free repair or replacement service for faults caused by product quality problems during the product warranty period.
Provide lifelong technical support and after-sales service to ensure that customers have no worries.

                    Safe, efficient, environmentally friendly and energy-saving power solutions

GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer

6kV,10kV, Series 14, Silicon Steel Core, Dry Type Distribution Transformer 

Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130°C(B)
(100°C)
155°C(F)
(120°C)
180°C(H)
(145°C)
30 6
6.3
6.6
10
10.5
11
±2x2.5%
±5%
0.4 Dyn11
Yyn0
130 605 640 685 2 4.0
50 185 845 900 965 2
80 250 1160 1240 1330 1.5
100 270 1330 1415 1520 1.5
125 320 1565 1665 1780 1.3
160 365 1800 1950 2050 1.3
200 420 2135 2275 2440 1.1
250 490 2330 2485 2665 0.9
315 600 2915 3125 3353 0.8
400 665 3375 3590 3850 0.8
500 790 4130 4390 4705 0.8
630 910 4975 5290 5660 0.7
630 885 5050 5365 5760 0.7 6.0
800 1035 5895 6265 6715 0.7
1000 1205 6885 7315 7885 0.7
1250 1420 8190 8720 9335 0.7
1600 1665 9945 10555 11320 0.7
2000 2075 12240 13005 14005 0.6
2500 2450 14535 15445 16605 0.6

*All parameters are for reference only; The final data will be customized according to the order.

H, Series SG(B)14, Silicon Steel Core, Dry Type Distribution Transformer 
Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130°C(B)
(100°C)
155°C(F)
(120°C)
180°C(H)
(145°C)
30 6
6.3
6.6
10
10.5
11
±2×25 0.4  Dyn11
Tyn0
130 605 640 685 2 4.0
50 185 845 900 965 2
80 250 1160 1240 1330 1.5
100 270 1330 1415 1520 1.5
125 320 1565 1665 1780 1.3
160 365 1800 1915 2050 1.3
200 420 2135 2275 2440 1.1
250 490 2330 2485 2665 0.9
315 600 2945 3125 3355 0.8
400 665 3375 2000 3850 0.8
500 790 4130 4390 4705 0.8
630 910 4975 5290 5660 0.7
630 885 5050 5365 5760 0.7 6.0
800 1035 5895 6265 6715 0.7
1000 1205 6885 7315 7885 0.7
1250 1420 8190 8720 9335 0.7
1600 1665 9945 10555 11320 0.7
2000 2075 12240 13005 14005 0.6
2500 2450 14535 15445 16605 0.6
*All parameters are for reference only; The final data will be customized according to the order.
 
H, Series SG(B)18, Silicon Steel Core, Dry Type Distribution Transformer 
Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130°C(B)
(100°C)
155°C(F)
(120°C)
180°C(H)
(145°C)
30 6
6.3
6.6
10
10.5
11
±2×2.5 0.4  Dyn11
Yyn0
105 605 640 685 2 4.0
50 155 845 900 965 2
80 210 1160 1240 1330 1.5
100 230 1330 1415 1520 1.5
125 270 1565 1665 1780 1.3
160 310 1800 1915 2050 1.3
200 360 2135 2275 2440 1.1
250 415 2330 2485 2665 0.9
315 510 2945 3125 3355 0.9
400 570 3375 3590 3850 0.8
500 670 4130 4390 4705 0.8
630 775 4975 5290 5660 0.7
630 750 5050 5365 5760 0.7 6.0
800 875 5895 6265 6715 0.7
1000 1020 6885 7315 7885 0.7
1250 1205 8190 8720 9335 0.7
1600 1415 9945 10555 11320 0.7
2000 1760 12240 13005 14005 0.6
2500 2080 14535 15445 16605 0.6
*All parameters are for reference only; The final data will be customized according to the order.
 
Series SCR(B)12, Silicon Steel Core, Dry Type Distribution Transformer 
Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130ºC (B)
(100ºC)
155ºC (F)
(120ºC)
180ºC (H)
(145ºC)
30 6
6.3
6.6
10
10.5
11
±2×2.5 0.4  Dyn11
Yyn0
150 670 710 760 2 4.0
50 215 940 1000 1070 2
80 295 1290 1380 1480 1.5
100 320 1480 1570 1690 1.5
125 375 1740 1850 1980 1.3
160 430 2000 2130 2280 1.3
200 495 2370 2530 2710 1.1
250 575 2590 2760 2960 0.9
315 705 3270 3470 3730 0.8
400 785 3750 3990 4280 0.8
500 930 4590 4880 5230 0.8
630 1070 5530 5880 6290 0.7
630 1040 5610 5960 6400 0.7 6.0
800 1215 6550 6960 7460 0.7
1000 1415 7650 8130 8760 0.7
1250 1670 9100 9690 10370 0.7
1600 1960 11050 11730 12580 0.7
2000 2440 13600 14450 15560 0.6
2500 2880 16150 17170 18450 0.6
*All parameters are for reference only; The final data will be customized according to the order.
 
Series SCR(B)14, Silicon Steel Core, Dry Type Distribution Transformer 
Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130ºC (B)
(100ºC)
155ºC (F)
(120ºC)
180ºC (H)
(145ºC)
30 6
6.3
6.6
10
10.5
11
±2×2.5 0.4  Dyn11
Yyn0
130 605 640 685 2 4.0
50 185 845 900 965 2
80 250 1160 1240 1330 1.5
100 270 1330 1415 1520 1.5
125 320 1565 1665 1780 1.3
160 365 1800 1915 2050 1.3
200 420 2135 2275 2440 1.1
250 490 2330 2485 2665 0.9
315 600 2945 3125 3355 0.8
400 665 3375 3590 3850 0.8
500 790 4130 4390 4705 0.8
630 910 4975 5290 5660 0.7
630 885 5050 5365 5760 0.7 6.0
800 1035 5895 6265 6715 0.7
1000 1205 6885 7315 7885 0.7
1250 1420 8190 8720 9335 0.7
1600 1665 9945 10555 11320 0.7
2000 2075 12240 13005 14005 0.6
2500 2450 14535 15445 16605 0.6
*All parameters are for reference only; The final data will be customized according to the order.
 
Series SCR(B)14, Silicon Steel Core, Dry Type Distribution Transformer 
Rated Power
(kVA)
Voltage Vector Group No-load Loss
(w)
Thermal insulation level No-load Current
(%)
Impedance at principal tapping
(%)
H.V
(kV)
Tapping L.V
(kV)
130ºC (B)
(100ºC)
155ºC (F)
(120ºC)
180ºC (H)
(145ºC)
30 6
6.3
6.6
10
10.5
11
±2×2.5 0.4  Dyn11
Yyn0
130 605 640 685 2 4.0
50 185 845 900 965 2
80 250 1160 1240 1330 1.5
100 270 1330 1415 1520 1.5
125 320 1565 1665 1780 1.3
160 365 1800 1915 2050 1.3
200 420 2135 2275 2440 1.1
250 490 2330 2485 2665 0.9
315 600 2945 3125 3355 0.8
400 665 3375 3590 3850 0.8
500 790 4130 4390 4705 0.8
630 910 4975 5290 5660 0.7
630 885 5050 5365 5760 0.7 6.0
800 1035 5895 6265 6715 0.7
1000 1205 6885 7315 7885 0.7
1250 1420 8190 8720 9335 0.7
1600 1665 9945 10555 11320 0.7
2000 2075 12240 13005 14005 0.6
2500 2450 14535 15445 16605 0.6
*All parameters are for reference only; The final data will be customized according to the order.
 
110kV, Silicon Steel Core, Dry Type Power Transformer 
 Application scope of the technical condition
  Product code    1RE.717.7240.1 Vector Group YNd11
  Model         SC12-10000/110 Frequency                50Hz
  Rated volume   10000kVA Installation type: indoor  
 Rated voltage   110±2×2.5%/10.5kV   Cooling means          AN/AF
 Rated current   52.5/549.9A  Insulation class         H
  Technical data
 Test data   Standard value
  No-load loss(kW) 22
 No-load current (%) 0.5
  Load loss(kW) (145ºC) 70
  Impedance voltage (%) 10.5
  High voltage test standard
       HV     Um/LI/AC 126/480/200
 High-pressure tail      HVN   Um/LI/AC 52/250/95
  Low pressure           LV     Um/LI/AC 12/75/35
  Weight(kg) 33000
*All parameters are for reference only; The final data will be customized according to the order.

GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
 
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
Anhui Shine Electric Power Technology Co., Ltd
 
Shine specializes in providing consulting, sales, and service for electrical products. We are committed to providing customers with comprehensive electrical solutions to meet the power needs of different industries and fields.
Our products cover electrical products such as transformers, ring main units, combiner boxes, inverters, and PCS. These products are widely used in the power system, industrial and mining enterprises, new energy, and other fields. We also have a sufficient inventory of spare parts and components to ensure that customers can receive prompt supplies when needed.
We have a professional technical team with deep knowledge and practical experience in the power industry, who can provide professional technical consultation and after-sales service to customers. Our service team always takes customer needs as the guide, actively responds to customer needs, and ensures customer satisfaction.
 
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer

GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer
GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer


GB1094 3 Phase Step Down Aluminium Dry Type Distribution Transformer1. Who we are?
We specialize in providing consulting, sales, and service for electrical products. We are committed to providing customers with comprehensive electrical solutions to meet the power needs of different industries and fields.

2.How can we guarantee quality?
We have comprehensive pre-sales and after-sales services. When we receive an order, we have standard procedure to provide client with a production and processing schedule within 3-4 days, including part names, delivery time, total assembly time, and testing plan.

3.What can you buy from us?
110kV-220kV Oil-immersed Power Transformer, Dry-type Transformer, Unpacked H Grade Dry Transformer, Oil-immersed Distribution Transformer, Pad-mounted Transformer, etc., and various spare parts.

4.Why should you buy from us?
As an enterprise specializing in power productions, we not only provide products, but also technical solutions as your need. We continuously focus on participating in and developing the construction of smart grids, striving to become excellent experts in solving power system problems with reliable quality, strict management, and efficient services. What's more, we have got many certificates like ISO-9000.

5.What services can we provide?
Power technical solutions, electric productions and spare parts, and E-learning class about the productions.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier